15-20 Defaulting the Description for a Control Output
LX Series Configuration Guide
Example
Defaulting the Description for a Control Output
Use the following commands to default a Control Output
Description for a specific control or for multiple controls.
X To configure a control output default description for a
specific control
Use the following command syntax:
Syntax hdam control <control_name> description
X To configure a control output default description for
multiple controls
Use the following command syntax:
Syntax hdam control port <port_number> slot [<slot_list>|all]
point [<
point_list>|all] description
where
Config:0 >>hdam control Floor2Lab description lab door 1
Config:0 >>hdam control 3_1_8 description lab door 2
Config:0 >>hdam control port 2 slot 1,2 point 1-4
description lab1
Config:0 >>hdam control port 2 slot all point all description
library second floor
control_name Specifies a Control Output Name. The default name for
an alarm input or control output is canonically derived
from the port number, slot number and point number.
For example, the default name for the 8th control
output on the 2
nd
slot of the HDAM being managed by
port 5 is 5_2_8.
port_number Specifies the HDAM port managing the 7204T.
slot_list Specifies a list of Slots whose points to configure a
description for. The list can contain single items (such
as 1,3,4) or ranges (such as 1-4), or a combination.