451-0308 MRV Communications, Inc. www.mrv.com 49
Appendix B - Factory Defaults
The following table provides the factory defaults for the LX-4000 Series.
Table 3 - LX-4000 Series Factory Defaults
Item Description
DIAG Port/local management port (default
settings)
The DIAG port (port 0) is the console manage-
ment port.
Auto Protocol Detect (APD) is disabled.
Autobaud is disabled.
9600/8/1/None.
Quick Start is enabled.
Access is Local.
Flow Control is Xon/Xoff.
All Ports Except Management and Modem
Ports (default settings)
Autobaud is disabled.
9600/8/1/None.
Access is Remote.
APD is disabled.
Flow Control is Xon/Xoff.
Modem Port (default settings) Autobaud is disabled.
Speed is 57600.
Access is Local.
APD is enabled.
Flow Control is CTS.