451-0308 MRV Communications, Inc. www.mrv.com 35
Configuring the LX-4000 Series for the First Time
Password> system
InReach>> config
Config:0>> interface 1
Intf 1-1:0>> telnet port #
NOTE: If you change the port number, be sure not to use a socket number assigned to another
application or daemon.
Accessing from a Terminal Attached to an LX-4000 Series Serial Port
Use the following procedure to access the command line interface port from a dumb terminal attached
to an LX Series serial port, which is set for access local, or dynamic:
1. Hit the return key several times to autobaud (if autobaud is enabled) the port and get the Login:
prompt.
2. Enter your login name. The default is InReach.
3. Enter your password. The default is access.
Additional Considerations
Other considerations include the following:
Setting up users
Authentication/Security
Configuring modem settings
For further information on these issues, refer to the LX-Series Commands Reference Guide, and to the
Support area of the MRV website at www.mrv.com.